Sale!
draeger logo hazmat resource

Draeger Tube Ammonia 0.25/a 8101711

$83.70

The Draeger Tube Ammonia 0.25/a 8101711 has a measurement range of 0.25 to 3 ppm. During measurements, color changes on the tube indicate the concentration level of the hazardous substance.

  • Box of 10 tubes
  • 2 year shelf life
Add to quote
SKU: 8101711 Category: Product Brand:

Description

The Draeger Tube Ammonia 0.25/a 8101711 is high precision. The Dräger sampling tubes and systems provide very reliable results, even with complex compounds and mixtures of substances.

Dräger-Tubes for Measuring Air Samples

Application Range

  • Standard Measuring Range: 0.25 to 3 ppm
  • Number of Strokes n: 10
  • Time for Measurement: approx. 1 min
  • Standard Deviation: ± 10 to 15 %
  • Color Change: yellow → blue

 

Ambient Operating Conditions

  • Temperature: 10 to 50 °C
  • Absolute Humidity: <  20 mg H2O / L

 

Reaction Principle

  • NH3 + pH indicator → blue reaction product

 

Cross Sensitivity

Other basic substances such as e.g. organic amines are indicated as well, but with different sensitivity

Dräger-Tubes for Measuring Liquid Samples

Application Range

Determination of Draeger ammonia tubes in water/waste water

  • Dräger-Tube: Ammonia 0.25/a
  • Measuring range: 1.5 to 10 mg/L
  • Number of Strokes (n): 10
  • Typical Stroke Time: 10 to 30 s
  • Measurement Time: approx. 200 s
  • Sample Volume: 200 mL
  • Color Change: yellow → blue
  • Temperature Range: 4 to 30 °C
  • pH-Measurement: necessary

 

Information of Measurement

Using acetic acid or sodium hydroxide solution, the pH-value has to be adjusted to the value of 10.2 – 10.3.

System Parameters (valid for pH 1.3)

Measurement Range [mg/L] Standard Deviation [%] Temperature [°C] Parameters
B C
1.5 to 10 30 4 to 7

8 to 12

13 to 17

18 to 24

25 to 30

3.427 2.926

2.578 1.895

1.397 1.409

0.815 0.918

0.989 0.774

 

Evaluation of Measurement

Calculate ammonia concentration:

Y[mg/L] = A • B • (X[ppm] + C)

Cross Sensitivity

Other basic substances are also indicated. Draeger Tube Ammonia 1.5 to 10 mg/L 8101711

Draeger Tube Ammonia 10 to 100 mg/L 8101711

Application Range

Determination of Draeger ammonia tubes in water/waste water

  • Dräger-Tube: Ammonia 0.25/a
  • Measuring range: 10 to 100 mg/L
  • Number of Strokes (n): 1
  • Typical Stroke Time: 10 to 30 s
  • Measurement Time: approx. 20 s
  • Sample Volume: 200 mL
  • Color Change: yellow → blue
  • Temperature Range: 4 to 30 °C
  • pH-Measurement: necessary

 

Information of Measurement

Using acetic acid or sodium hydroxide solution, the pH-value has to be adjusted to the value of 10.2 – 10.3.

System Parameters (valid for pH 1.3)

Measurement Range [mg/L] Standard Deviation [%] Temperature [°C] Parameters
B C
10 to 100 30 4 to 7

8 to 12

13 to 17

18 to 24

25 to 30

61.34 0.826

40.46 0.310

29.37 0.943

27.59 0.463

18.11 -0.123

 

Evaluation of Measurement

Calculate ammonia concentration:

Y[mg/L] = A • B • (X[ppm] + C)

Cross Sensitivity

Other basic substances are also indicated.

Draeger Ammonia 0.25/a Tubes – 8101711

  • Simple to use
  • Requires no calibration
  • Inexpensive and portable
  • Wide variety of gases and vapors
  • 70 years of proven technology
  • Most Trusted – Draeger-Tubes have been leading the way in gas detection for over 60 years.
  • Widest Range – Over 200 different Draeger-Tubes are available for measuring over 500 gases and vapors.
  • Hassle-Free Operation – No calibration, no lubrication, no special maintenance. Always ready to go.

 

Accurate and reliable results

Draeger-Tubes with the Accuro Pump deliver the most accurate results. 60+ years of manufacturing colorimetric tubes. The bellows pump design delivers consistent volume. Individual calibration of each batch of Draeger gas detection tubes Ammonia included, accomplishes quality assurance. Every batch undergoes testing at regular intervals, throughout the two year shelf life, to guarantee accuracy over the entire life of the tubes.

Draeger Ammonia Detector Tubes

Collect the hazardous substances in the air by using a suitable medium such as activated carbon, silica gel, or molecular sieves. Then analyze the sample in a laboratory with the aid of instrumental analysis.

Suitable for complex cases

Draeger sampling tubes and systems allow identification and measurement of different substances even under difficult conditions. Use Draeger Tubes to simultaneously and accurately measure very complex mixtures of substances or cases in which several similar substances are present. Dräger Tube Ammonia 0.25/a has the Draeger SKU 8101711.

Dräger accuro

Fast measurement with one hand: The Dräger-Tube pump accuro allows you to use the established Dräger-Tubes to take measurements under extreme conditions. The easy to use Draeger Tube 8101711 Ammonia 0.25/a has already undergone calibration. It forms a perfect unit with the Dräger-Tube pump including the Draeger Safety Ammonia Tube.

 

Ammonia Draeger Tubes & CMS Handbook Draeger Tubes Apple App Draeger Tubes Google Play App
Ammonia Draeger Tubes & CMS Handbook App Store – Draeger Tubes App Play Store – Draeger Tubes App



What are Draeger Tubes?

Dräger-Tubes are glass vials that contain a chemical reagent that reacts to a specific chemical or family of chemicals. Draeger detector tubes are a cost-effective, fast, and reliable way to measure toxic gases anywhere.

Draeger Tube Ammonia 0.25/a Gas Detection Tube 8101711

For more information about this product, contact us today +1(805) 617-0987.

Additional information

Weight 1 lbs
Dimensions 7 × 2 × 2 in