Draeger Tube Petroleum Hydrocarbons 10/a 8101691
Original price was: $110.00.$99.00Current price is: $99.00.
The Draeger Tube Petroleum Hydrocarbons 10/a 8101691 has a measurement range of 10 to 300 ppm for n-octane. During measurements, color changes on the tube indicate the concentration level of the hazardous substance.
- Box of 10 tubes
- 2 year shelf life
Description
The Draeger Tube Petroleum Hydrocarbons 10/a 8101691 is high precision. The Dräger sampling tubes and systems provide very reliable results, even with complex compounds and mixtures of substances.
Application Range
- Standard Measuring Range: 10 to 300 ppm for n-octane.
- Number of Strokes n: 2
- Time for Measurement: approx. 1 min
- Standard Deviation: ± 25 %
- Color Change: white → brownish green
Ambient Operating Conditions
- Temperature: 15 to 30 °C
- Absolute Humidity: 1 to 20 mg H2O / L
Reaction Principle
- C8H18 + I2O5 → I2
Cross Sensitivity
In addition to n-octane other organic or inorganic compounds are indicated as well.
- 50 ppm n-hexane indicates a discoloration of approx. 70 ppm
- 100 ppm n-heptane indicates a discoloration of approx. 150 ppm
- 10 ppm iso-octane indicates a discoloration of approx. 15 ppm
- 100 ppm iso-octane indicates a discoloration of approx. 150 ppm
- 200 ppm iso-octane indicates a discoloration of approx. 350 ppm
- 50 ppm n-nonane indicates a discoloration of approx. 50 ppm
- 50 ppm perchloroethylene indicates a discoloration of approx. 50 ppm
- 30 ppm CO indicates a discoloration of approx. 20 ppm
Dräger-Tubes for Measuring Liquid Samples
Application Range
Determination of diesel fuels in water/waste water
- Dräger-Tube: Petroleum hydrocarbons 10/a
- Measuring range: 0.5 to 5 mg/L
- Number of Strokes (n): 8
- Typical Stroke Time: 30 to 60 s
- Measurement Time: approx. 360 s
- Sample Volume: 200 mL
- Color Change: white → brown green
- Temperature Range: 5 to 25 °C
- pH-Measurement: not necessary
System Parameters
Measurement Range [mg/L] | Standard Deviation [%] | Temperature [°C] | Parameters B C |
0.5 to 5 | 30 | 5 to 25 | 0.089 0 |
Readings > 50 ppm give qualitative results, only
Evaluation of Measurement
Calculate diesel fuel concentration:
Y[mg/L] = A • B • (X[ppm] + C)
Cross Sensitivity
The sensitivity is lower for ethyl acetate, diesel oil, hydrogen sulfide, and toluene. Perchloroethylene shows higher sensitivity. Draeger Tube Diesel Fuels 0.5 to 5 mg/L 8101691
Draeger Tube Gasoline 0.1 to 2 mg/L 8101691
Application Range
Determination of gasoline in water/waste water
- Dräger-Tube: Petroleum hydrocarbons 10/a
- Measuring range: 0.1 to 2 mg/L for n-octan
- Number of Strokes (n): 2
- Typical Stroke Time: 30 to 60 s
- Measurement Time: approx. 90 s
- Sample Volume: 200 mL
- Color Change: white → brown green
- Temperature Range: 5 to 25 °C
- pH-Measurement: not necessary
System Parameters
Measurement Range [mg/L] | Standard Deviation [%] | Temperature [°C] | Parameters B C |
0.1 to 2 | 30 | 5 to 25 | 0.010 0 |
Evaluation of Measurement
Calculate gasoline concentration:
Y[mg/L] = A • B • (X[ppm] + C)
Cross Sensitivity
The sensitivity is lower for ethyl acetate, diesel oil, hydrogen sulfide, and toluene. Perchloroethylene shows higher sensitivity.
Draeger Tube Jet Fuels (Kerosene) 0.5 to 5 mg/L 8101691
Application Range
Determination of jet fuels in water/waste water
- Dräger-Tube: Petroleum hydrocarbons 10/a
- Measuring range: 0.5 to 5 mg/L
- Number of Strokes (n): 4
- Typical Stroke Time: 30 to 60 s
- Measurement Time: approx. 180 s
- Sample Volume: 200 mL
- Color Change: white → brown green
- Temperature Range: 5 to 25 °C
- pH-Measurement: not necessary
System Parameters
Measurement Range [mg/L] | Standard Deviation [%] | Temperature [°C] | Parameters B C |
0.5 to 5 | 25 | 5 to 25 | 0.062 0 |
Evaluation of Measurement
Calculate jet fuel concentration:
Y[mg/L] = A • B • (X[ppm] + C)
Cross Sensitivity
The sensitivity is lower for ethyl acetate, diesel oil, hydrogen sulfide, and toluene. Perchloroethylene shows higher sensitivity.
Draeger Tube n-Octane 0.1 to 2 mg/L 8101691
Application Range
Determination of n-octane in water/waste water
- Dräger-Tube: Petroleum hydrocarbons 10/a
- Measuring range: 0.1 to 2 mg/L
- Number of Strokes (n): 2
- Typical Stroke Time: 30 to 60 s
- Measurement Time: approx. 90 s
- Sample Volume: 200 mL
- Color Change: white → brown green
- Temperature Range: 5 to 25 °C
- pH-Measurement: not necessary
System Parameters
Measurement Range [mg/L] | Standard Deviation [%] | Temperature [°C] | Parameters B C |
0.1 to 2 | 30 | 5 to 25 | 0.010 0 |
Evaluation of Measurement
Calculate n-octane concentration:
Y[mg/L] = A • B • (X[ppm] + C)
Cross Sensitivity
The sensitivity is lower for ethyl acetate, diesel oil, hydrogen sulfide, and toluene. Perchloroethylene shows higher sensitivity.
Dräger-Tubes for Measuring Soil Samples
Application Range
Determination of diesel fuels in soil
- Dräger-Tube: Petroleum hydrocarbons 10/a
- Measuring range: qualitative
- Number of Strokes (n): maximum 10
- Typical Stroke Time: 30 to 60 s
- Measurement Time: approx. 45 to 450 s
- Sample Volume: 20 g
- Color Change: white → brown green
- Temperature Range: 5 to 25 °C
- pH-Measurement: not necessary
Information of Measurement
– 20 g soil is suspended completely with 100 mL de-ionized water.
– The precipitate must rest for approx. 1 minute, until the particles have settled to the bottom; the liquid above the particles has to be filled into the was bottle
– The remaining precipitate has to be shaken two times with 50 mL de-ionized water and the liquid above the particles has to be filled into the was bottle
– The gas wash bottle is filled up with de-ionized water up to 200 mL mark.
Evaluation of Measurement
The measurement evaluation is qualitative (yes or no)
Cross Sensitivity
Diesel oil, ethyl acetate, perchloroethylene, hydrogen sulfide and toluene are also indicated. Draeger Tube Diesel Fuels qualitative in soil 8101691
Draeger Tube Gasoline qualitative in soil 8101691
Application Range
Determination of gasoline in soil
- Dräger-Tube: Petroleum hydrocarbons 10/a
- Measuring range: qualitative
- Number of Strokes (n): maximum 10
- Typical Stroke Time: 30 to 60 s
- Measurement Time: approx. 45 to 450 s
- Sample Volume: 20 g
- Color Change: white → brown green
- Temperature Range: 5 to 25 °C
- pH-Measurement: not necessary
Information of Measurement
– 20 g soil is suspended completely with 100 mL de-ionized water.
– The precipitate must rest for approx. 1 minute, until the particles have settled to the bottom; the liquid above the particles has to be filled into the was bottle
– The remaining precipitate has to be shaken two times with 50 mL de-ionized water and the liquid above the particles has to be filled into the was bottle
– The gas wash bottle is filled up with de-ionized water up to 200 mL mark.
Evaluation of Measurement
The measurement evaluation is qualitative (yes or no)
Cross Sensitivity
Diesel oil, ethyl acetate, perchloroethylene, hydrogen sulfide and toluene are also indicated.
Draeger Tube Jet Fuels (Kerosene) qualitative in soil 8101691
Application Range
Determination of jet fuels in soil
- Dräger-Tube: Petroleum hydrocarbons 10/a
- Measuring range: qualitative
- Number of Strokes (n): maximum 10
- Typical Stroke Time: 30 to 60 s
- Measurement Time: approx. 45 to 450 s
- Sample Volume: 20 g
- Color Change: white → brown green
- Temperature Range: 5 to 25 °C
- pH-Measurement: not necessary
Information of Measurement
– 20 g soil is suspended completely with 100 mL de-ionized water.
– The precipitate must rest for approx. 1 minute, until the particles have settled to the bottom; the liquid above the particles has to be filled into the was bottle
– The remaining precipitate has to be shaken two times with 50 mL de-ionized water and the liquid above the particles has to be filled into the was bottle
– The gas wash bottle is filled up with de-ionized water up to 200 mL mark.
Evaluation of Measurement
The measurement evaluation is qualitative (yes or no)
Cross Sensitivity
Diesel oil, ethyl acetate, perchloroethylene, hydrogen sulfide and toluene are also indicated.
Draeger Petroleum Hydrocarbons 10/a Tubes – 8101691
- Simple to use
- Requires no calibration
- Inexpensive and portable
- Wide variety of gases and vapors
- 70 years of proven technology
- Most Trusted – Draeger-Tubes have been leading the way in gas detection for over 60 years.
- Widest Range – Over 200 different Draeger-Tubes are available for measuring over 500 gases and vapors.
- Hassle-Free Operation – No calibration, no lubrication, no special maintenance. Always ready to go.
Accurate and Reliable Results
Draeger-Tubes with the Accuro Pump deliver the most accurate results. 60+ years of manufacturing colorimetric tubes. The bellows pump design delivers consistent volume. Individual calibration of each batch of Draeger Gas Detection Tubes Petroleum Hydrocarbons included accomplishes quality assurance. Then, every batch undergoes testing at regular intervals, throughout the two year shelf life, to guarantee accuracy over the entire life of the tubes.
Draeger Petroleum Hydrocarbons Detector Tubes
Collect the hazardous substances in the air by using a suitable medium such as activated carbon, silica gel, or molecular sieves. Then, analyze the sample in a laboratory with the aid of instrumental analysis.
Suitable for Complex Cases
Draeger sampling tubes and systems allow identification and measurement of different substances even under difficult conditions. Use Draeger Tubes to simultaneously and accurately measure very complex mixtures of substances or cases in which several similar substances are present. Dräger Tube Petroleum Hydrocarbons 10/a has the Draeger SKU 8101691.
Dräger accuro
Fast measurement with one hand: The Dräger-Tube pump accuro allows you to use the established Dräger-Tubes to take measurements under extreme conditions. The easy to use Draeger Tube 8101691 Petroleum Hydrocarbons 10/a has already undergone calibration. It forms a perfect unit with the Dräger-Tube pump including the Draeger Safety Petroleum Hydrocarbons Tube.
- Dräger Accuro Pump info here >>
- Draeger Accuro Pump Kit info here >>
Petroleum Hydrocarbons Draeger Tubes & CMS Handbook |
App Store Draeger Tubes App |
Play Store Draeger Tubes App |
What are Draeger Tubes?
Dräger-Tubes are glass vials that contain a chemical reagent that reacts to a specific chemical or family of chemicals. Draeger detector tubes are a cost-effective, fast, and reliable way to measure toxic gases anywhere.
Draeger Petroleum Hydrocarbons 10/a Gas Detection Tube 8101691
For more information about this product, contact us today +1(805) 617-0987.
Additional information
Weight | 1 lbs |
---|---|
Dimensions | 7 × 2 × 2 in |