draeger logo hazmat resource

X-am 8000 Multi-Gas Detector

$3,243.00

The Draeger X-am 8000 Multi-Gas Detector detects toxic and flammable gases as well as vapors and oxygen all at once.

Reference brochure for different configurations and accessories. Just click “Request a quote”

Description

This is the Dräger X-am 8000 Multi-Gas Detector.


PRODUCT BROCHURE

The Draeger X-am 8000 is a 1 to 7 gas detector. It measures for toxic and flammable gases, Oxygen, and volatile organic compounds. It has the ability to operate in diffusion mode or with the internal pump.

Multi-gas detector

  • ​1- to 7 gas detection device
  • for clearance measurement
  • detection of toxic and combustible gases as well as vapors and oxygen

Draeger specially designed the X-am 8000 for use with a pump and optimized it for clearance measurement

The Dräger equipped the X-am 8000 with a very powerful pump. You can connect it with hoses of up to 45 meters in length. A pump adapter makes it easy to switch between diffusion and pump mode at any time. This means that you only operate the pump when you actually need it. That saves energy, reduces wear and tear, and extends the lifespan of the pump.

Handy and durable, the Dräger X-am 8000 is intuitive to operate single-handedly using three function keys. The easy-to-read color display clearly lays out all the information for you.

The multi-gas detector also features advanced software functions including change of measurement gas for PID, CatEx and IR sensor during operation. This is based on an on-board library and a convenient assistant to hide unused sensor channels and adapt the flexible instrument to the measurement task.

Standard accessories include a sturdy shoulder strap so you can comfortably carry the X-am 8000. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.

Clearance measurement, release and documentation in no time

The X-am 8000 effectively supports various applications with specially developed assistant functions that guide you through each process step by step. During clearance measurement, for example, the smart assistant calculates the necessary flooding time for the device and probe (FKM hose) based on parameters such as measuring gases, temperature limits, and the indicated hose length. Additionally, customer defined flooding times are also possible.

When monitoring for potentially high methane concentrations, an optional automatic measurement range switch makes it easier to take a reading: If the Cat-Ex sensor measures values above 100 % LEL, the display switches to the range of 0 to 100 vol %. A similar function to measure in % LEL and vol % simultaneously is also available for the IR EX ES sensor.

An additional useful tool is CSE Connect. It combines an app, specially designed for the X-am 8000, with a cloud-computing solution. Measuring jobs can be quickly and easily transferred to the app using an online application.

An optional Bluetooth module in the Dräger X-am 8000 can automatically transfer measured values to the CSE Connect app. You can also easily and conveniently use the app to create measurement reports. This saves time and helps you manage your measuring tasks during clearance measurements more efficiently.

Clear signaling design

​The signal system of the Dräger X-am 8000 is based on a clear color code, in accordance with the requirements of EN 60079-29-1, EN 45544-1 and EN 50104:

  • Red light = gas alarm
  • Yellow light = device-related alarm, e.g. low battery
  • Green light = device is ready for use

 

The green glow of the D-light allows you to see from a distance whether the device has been properly tested and is ready for use.
In case of an alarm, the X-am 8000 alerts you with colorful warning LEDs, a loud horn (100 dB(A) at a distance of 30 cm), and clearly palpable vibration. Optionally, four preset hazard symbols are available for the display which explicitly indicate the presence of explosive or toxic gas hazards, for example. This allows the user to easily recognize the type of hazard based purely on the symbol displayed.

The X-am 8000 has an impact detection system. The event report indicates whenever severe mechanical impacts have occurred that might result in functional impairments of the device or the sensors. These are also documented in the data logger. With this information, a device operator can specifically check the device. Responders can also lock the instrument after a detected impact as well.

Economical Fleet Management

​Responders can simply and quickly carry out Bumptest and calibration using the Dräger X-dock calibrating station. Its low test gas consumption keeps operating costs to a minimum.

Its reporting function and numerous other useful features make the X-dock Manager PC software a smart addition to any fleet management operation. To identify devices in your fleet, you can either use tried and tested barcodes or an integrated RFID transponder.

Specialist for high and low hydrocarbon concentrations

To measure hard-to-detect hydrocarbons, you can fit the Dräger X-am 8000 with one of two high-performance PID sensors. The PID HC covers a measurement range of 0 to 2,000 ppm (isobutene). The PID LC ppb is for a measurement range of 0 to 10 ppm (isobutene) with a high resolution in the range below 1 ppm.

For benzene-specific measurements, responders can use the X-am 8000 with a pre-tube. The advantage: You only need one measuring device for this application, which significantly reduces the costs of purchasing, maintaining and transporting devices in use. A built-in assistant supports the use of pre-tubes.

Inductive charging protects against wear and tear

The X-am 8000 features inductive charging. This makes it easier to operate and increases the lifespan of the device. Issues like corrosion and contact problems in the charging cradle are a thing of the past. You can charge (outside of explosion-hazard zones) and measure at once, e.g, when using inside vehicles or on machinery.

The charging cradles can connect with one another, take up minimal space, and are compatible with existing Dräger X-am series cradles.

Dräger X-am 8000 IR Ex, O2, CO/H2S, battery, inductive charger, internal pump, pump adaptor

Features:

  • Five sensor slots to measure up to seven gases
  • Three-button, one-hand operation
  • Rechargeable Li-Ion battery with induction charging
  • Internal pump that activates when the pump adapter engages
  • Pump draws sample from up to 45 m (147 ft.)

 

This product meets the requirements for the California Standardized Equipment List – SEL 2.1.1.
CONFINED SPACE OSHA STANDARD Four Gas: Continuous monitoring, independent displays, built-in alarms, minimum of 10 feet of tubing and sampling wand. Referred to as “Four-in-One” Kits: (O2 Presence in Percent; Combustible Vapor in LEL; CO presence; H2S presence)

To see all of the SEL products we carry visit here >>

Need More Information?

For more information about the X-am 8000 Multi-Gas Detector, contact us today!

Additional information

Weight 2 lbs
Dimensions 3 × 8 × 2 in