With the robust Draeger Pac 8000 Gas Detector – Exotic Single-Gas, you’ll be prepared for tough conditions. This nondisposable, personal single-gas detector is a reliable and precise instrument that detects hazardous concentrations of 29 different gases, including special gases like H2, NO2, O3, and COCl2. 

Dräger Pac 8000 Single-Gas Detector

Measured data can easily be transmitted to the Dräger Gas Detection Connect system via Bluetooth. Contact us for your specific sensor and accessory mix.

Key Facts

Sensor type:
Measurable gases:
Application:
Lifetime:

Single-Gas Detector
NO, CO2, Cl2, HCN, NH3, PH3, OV, OV-A, NO2 LC, Ozone, Phosgene
Personal Air Monitoring
unlimited

Advance Sensor Technology

  • Built for tough environments
  • Reliable and reusable single-gas detector
  • Bluetooth data transfer to dräger gas detection connect system

Strong performance for maximum safety

You can count on the Dräger Pac 8000 Single Gas Monitor to provide reliable, precise readings even in extreme conditions. Its powerful sensors, with a fast T-90 response time, ensure quick reactions.

In addition to the standard alarms, you can define extra alarm thresholds for TLV/TWA* (Threshold Limit Values / Time Weighted Average) and STEL* (Short Term Exposure Limit).

Sensors for special gases

The Pac 8000 is compatible with sensors for gases like hydrogen (H₂), carbon dioxide (CO₂), chlorine (Cl₂), hydrogen cyanide (HCN), ammonia (NH₃), nitrogen dioxide (NO₂), phosphine (PH₃), and organic vapors (OV/OV-A).

It’s especially effective with special gases—detecting ozone (O₃) from as low as 0.02 ppm, phosgene (COCl₂) from 0.01 ppm, and nitrogen dioxide (NO₂) from 0.04 ppm.

Hazmat Resource can help you find the right accessories to keep your detection equipment powered and ready for any operation.

We supply certified instruments built for precision, safety, and durability — from portable detectors to fixed monitoring systems. Contact us today to find the right setup.
DRÄGER | HAZCAT | REDWAVE | AGILENT — trusted brands for your safety program.
Fast Quote

Robust design – even for the toughest conditions

The Pac 8000 is built for tough environments. Its sensors withstand air pressures from 700 to 1,300 mbar, while a membrane filter protects against dust and liquids. The shock-proof, chemical-resistant housing meets IP68 standards for durability.

Dräger pac 8000 Calibration Hazmat Resource

Firefighter & Hazmat Teams

Draeger Pac 8000 Price Hazmat Resource

Industrial & Commercial

Easy handling thanks to clear user guidance

The D-Light shows if the device is functioning properly and ready for use. Each sensor variant also has clear color coding on the housing to help reduce the risk of errors.

User-friendly display with all important information

The large, non-verbal display shows gas concentration, unit, and battery level. Bright backlighting makes it easy to read even in low-light conditions.

360° alarm with various functions

When the Dräger Pac 8000 detects hazardous gas levels, it triggers a loud audible alarm, flashing visual signals, and a strong vibration to ensure you’re alerted. Bright LEDs on the top and bottom make the alarm visible from all directions, and the sound reaches up to 90 dB at 30 cm. The display shows peak gas concentration readings in real-time, and past alarms can be accessed later—even after they’ve been acknowledged.

Data logger and event logger for analyses and reports

The Pac 8000 logs gas concentrations and event timestamps, which can be downloaded to a PC for analysis. With the Gas Detection Connect platform and X-dock stations, data is synced to a cloud-based system—accessible anytime, anywhere for streamlined asset management.

Bluetooth communication

With Bluetooth capability, the new Pac 8000 allows real-time data transmission to the Dräger Gas Detection Connect platform. You can track the device location via the Connect gateway app, and integrate it with third-party applications using the OpenGATT protocol.

Economical operational costs

Every version of the Dräger Pac 8000 comes with a highly durable DrägerSensor XXS and a long-lasting battery.

A special membrane filter shields the device from water, dust, and other particles. If the filter gets dirty, it can be replaced quickly and easily, keeping downtime to a minimum and the device ready for use.

Fast function test saves time and money

Function tests and Dräger Pac 8000 calibration are easy and efficient with the Dräger X-dock calibration station. Automatic bump tests save time and test gas thanks to their short duration and low consumption. Simply place the Pac 8000 in the station, and it automatically selects the right settings.

Detect 38 Substances

  • 1,3-Butadiene
  • 2-Propanol
  • 2-Propenenitrile
  • Acetaldehyde
  • Acetic acid ethenyl ester
  • Acetylene
  • Ammonia (anhydrous)
  • Ammonia solution 25%
  • Arsine
  • Bromine (gaseous)
  • Carbon dioxide
  • Chlorine
  • Chlorine dioxide
  • Diborane
  • Epichlorohydrin
  • Ethanol
  • Ethyl ether
  • Ethylene
  • Ethylene oxide
  • Fluorine
  • Formaldehyde
  • Hydrogen
  • Hydrogen cyanide (anhydrous)
  • Hydrogen selenide (as Se)(anhydrous)
  • i-butene
  • Methanol
  • Methyl methacrylate
  • Nitric oxide
  • Nitrogen dioxide
  • Ozone
  • Phosgene
  • Phosphine
  • Propylene
  • Propylene oxide

About Draeger

Dräger manufactures medical and safety technology products. In so doing, Draeger protects, supports, and saves people’s lives around the world with fire departments, hazmat, and emergency services. Founded in Lübeck in 1889, Dräger has grown into a worldwide, listed enterprise. It is in its fifth generation as a family-run business. Dräger has more than 15,000 employees worldwide and is present in over 190 countries around the globe. In 2020, the company generated net sales of around EUR 3.4 billion. Hazmat responders all over the world use Dräger technology. It operates in around 50 countries with its own sales and service companies directly on location where its customers are. HazMat teams rely on HAZMAT Resource, get on-board and request a quote today!

Dräger VOICE – your hazmat-based safety product finder

Dräger HazMat VOICE is an essential tool for the safe handling of hazardous materials. One click and you’ll receive relevant information and specific recommendations of safety equipment for more than 1,500 hazardous substances in its database. Give it a try – it is so simple https://www.draeger.com/en-us_us/Substances

The Dräger Pac 8000 series includes:

  • Draeger nh3 sensor 8328277
  • Draeger no2 sensor 8328275
  • Draeger hcn sensor 8328276
  • Draeger ph3 sensor 8326355
  • Draeger ci2 sensor 8326352
  • Draeger cocl2 sensor 8326360
  • Draeger co2 sensor 8326351
  • Draeger no sensor 8326350
  • Draeger ov sensor 8326356
 

Need More Information?

For more information about the available Draeger Pac 8000 price, accessories, and Draeger Pac 8000 calibration needs, contact us today!

Cal OES MEL List – Firescope Hazardous Materials Minimum Equipment List (MEL)

This product meets the requirements for the Firescope MEL List. To see all of the MEL products that HAZMAT Resource provides, visit our California MEL List page >>

Cal OES MEL 2.3.4 PHOSPHINE: Continuous monitoring. 

Requires 1 gas detector capability for each Type 1 and Type 2 teams.

Draeger Pac 8000 Gas Detector - Exotic Single-Gas

A gas detector’s purpose is to monitor the air for hazardous gases and alert people if dangerous levels are present. It helps protect workers from toxic, flammable, or oxygen-deficient atmospheres by giving an early warning so they can take action before it becomes life-threatening.

Additional information

Weight 1 lbs
Dimensions 10 × 10 × 10 in
Select Single Gas

Hydrogen Cyanide (HCN), Ammonia (NH3), Nitrogen Dioxide (NO2), Phosphine (PH3), Chlorine (CL2), Phosgene (COCL2), Ozone (O3), Carbon Dioxide (CO2), Nitric Oxide (NO), Organic Vapors (OV), Organic Vapors (OV-A)

You may also like…