Sale!

Draeger Fumigation Test Kit II – 8103380 Refill

$229.00

Draeger Fumigation Test Kit II – 8103380 Dräger-Tubes: formaldehyde, phosphine, hydrocyanic acid, methyl
bromide, ethylene oxide; measurement approximately 4 minutes.

  • Dräger Fumigation Test Set refills include 5 tubes mounted in a rubber sleeve ready for use.
  • Draeger Tube accuro pump and adapter sold separately.
Add to quote

Description

Risks and potential dangers at a glance: The Dräger Fumigation Test Set II allow the measurement of five different gases at the same time.

Dräger Simultaneous Test Set

  • ​Parallel measurement of five gases
  • Air is simultaneously drawn with Dräger-Tube pump
  • For different combinations of organic and inorganic gases
  • 2 different Draeger Fumigation Test Set available

Simultaneous measurement

The Dräger-Tube® measurement system provides an easy method for testing containers and other spaces for the presence of fumigation agents. A specially developed measuring strategy allows for the detection of typical fumigation agents even when the chemical is unknown. The Dräger Fumigation Test Set can be equipped with all of the necessary components for this measurement.

System solution

  • Each five tube set is comprised of tubes specially calibrated as a system to provide rapid results in the presence of select gases and vapors. Gases and vapors present below the threshold of the first calibration mark may not be indicated.

Fast results

  • The Simultaneous Test Set I Fumigation device delivers fast and reliable results for different combinations of organic and inorganic gases.

Draeger 8103380, Simultaneous test fumigation. The Draeger Fumigation Test Kit 2 can be used with the Dräger Simultaneous Test Kit.

Dräger HazMat Simultest Kit available https://hazmatresource.com/product/field-testing-and-detection/draeger-hazmat-simultest-kit/

HAZMAT Resource Download PDF icon Draeger Tubes App Store icon Draeger Tubes icon Google Play
Draeger Tubes & CMS Handbook App Store – Draeger Tubes App Play Store – Draeger Tubes App

 

Draeger Fumigation Test Kit II
Benefits
To prevent goods from being damaged by animals such as insects and other disease carriers, containers are flooded with toxic or suffocating gases.

Fumigants are highly toxic and harmful to the health in many ways. To ensure adequate protection, the concentration of the fumigants used must be measured. This is relevant for all personnel present during:

  • the start or finish of the fumigation process
  • the opening of transport containers or other confined spaces
  • the loading or unloading of fumigated products from transport containers
  • the removal of fumigated goods from packaging materials
  • transportation (in case of leakages)

Suitable measurement instruments are used to determine the type and concentration of fumigants before opening a container or entering other spaces. Thereby, it is important to check the Oxygen concentration in the container or other spaces. When inert gases have been used, they will displace Oxygen and this results in a very high probability of suffocation. A leakage in one individual package is one example of a relatively simple cause for this.

Mobile and quick
The well-known Dräger-Tube measuring method is an easy way to perform measurements. In only a few minutes, the concentration of the fumigants within the container can be determined. Depending on the concentration measured, the decision can be made whether the container or space can be entered or ventilated.

Even when a container has not been declared correctly or the labeling is no longer legible, the Dräger measuring strategy will assist in the identification and detection of the fumigation agents.

Easy to use
For several decades, Dräger-Tubes have been renowned for their ease of use and high degree of measurement accuracy. Even without special training, the Dräger-Tubes, which were especially developed for this application, provide reliable test results. Dräger-Tubes are ready for use at any time. All that is needed are the corresponding tubes, the Dräger accuro® hand pump, and the Dräger bar probe. By comparing the color
change within the detector tube to the printed scale, an estimation of the concentration can be made.

Recommended measurement strategy
If the fumigant is known, the corresponding Dräger-Tube is chosen and the measurement carried out as instructed. If the measurement result is too high, then the container or space should be ventilated. A new measurement should be taken atperiodic intervals and, when the concentrationis low enough, the container or room can be released for entry. If the concentration detected is below the defined maximum limit, the container or room can be opened and entered.

The measurement of fumigants should take place while the container is still closed. To do this, insert the Dräger Bar Probe (order code 83 17 188) e.g. through the rubber seal of the container door. The probe should be used to lift the rubber seal of the container at its lowest point and pushed as far as possible into the container. The Dräger-Tubes should then be prepared for measurement and attached to the bar probe. The
necessary pump strokes for the measurement should then be made by using the Dräger gas detection pump.

If the fumigant is not known, the use of the Dräger Simultest Fumigation is recommended to determine which chemical has been used. This test set allows for the measurement of five typical fumigation agents at the same time:

  • Ammonia or Ethylene Oxide
  • Methyl Bromide
  • Hydrocyanic Acid
  • Phosphine
  • Formaldehyde

In addition, the following Dräger-Tubes should be used for the measurement of Ethylene Oxide, Carbon Dioxide, and Sulfuryl Fluoride:

  • Ethylene Oxide 1/a Measuring range from 1 to 15 ppm
  • Carbon Dioxide 0,1 %/a Measuring range from 0.1 to 1.2 Vol.-%
  • Sulfuryl Fluoride 1/a Measuring range from 1 to 5 ppm

When one or more gases are present, the container or space should be ventilated with air before entry and individual Dräger-Tubes used to test the concentrations of the corresponding gases periodically. If personnel should be equipped with personal air monitors for the measurement of Oxygen, Dräger offers a complete line of measurement and warning devices equipped with electrochemical sensors for this purpose.

To determine a potential risk of explosion, Dräger measurement and warning devices equipped with an infrared Ex-sensor should be used. Gas detectors that use catalytic ex-sensors are not appropriate as they do not operate in inert atmospheres.

Additional information

Weight 1 lbs
Dimensions 8 × 8 × 4 in

You may also like…