Sale!
draeger logo hazmat resource

Draeger Tube Petroleum Hydrocarbons 100/a 6730201

$85.50

The Draeger Tube Petroleum Hydrocarbons 100/a 6730201 has a measurement range of 100 to 2500 ppm for n-octane. During measurements, color changes on the tube indicate the concentration level of the hazardous substance.

  • Box of 10 tubes
  • 2 year shelf life
Add to quote
SKU: 6730201 Category: Product Brand:

Description

The Draeger Tube Petroleum Hydrocarbons 100/a 6730201 is high precision. The Dräger sampling tubes and systems provide very reliable results, even with complex compounds and mixtures of substances.

Dräger-Tubes for Measuring Air Samples

Application Range

  • Standard Measuring Range: 100 to 2,500 ppm for n-octane
  • Number of Strokes n: 2
  • Time for Measurement: approx. 30 s
  • Standard Deviation: ± 10 to 15 %
  • Color Change: white → green

 

Ambient Operating Conditions

  • Temperature: 0 to 40 °C
  • Absolute Humidity: < 30 mg H2O / L

 

Reaction Principle

  • C8H18 + I2O5 → I2

 

Cross Sensitivity

Many other petroleum hydrocarbons are indicated as well, but with different sensitivities. It is impossible to differentiate between them. Aromatics are indicated, but only with low sensitivities. Carbon monoxide is indicated in comparable concentrations with about half the sensitivity.

Dräger-Tubes for Measuring Liquid Samples

Application Range

Determination of n-octane in water/waste water

  • Dräger-Tube: Petroleum Hydrocarbons 100/a
  • Measuring range: 2 to 25 mg/L
  • Number of Strokes (n): 2
  • Typical Stroke Time: 30 to 45 s
  • Measurement Time: approx. 75 s
  • Sample Volume: 200 mL
  • Color Change: white → brown green
  • Temperature Range: 5 to 25 °C
  • pH-Measurement: not necessary

 

System Parameters

Measurement Range [mg/L] Standard Deviation [%] Temperature [°C] Parameters
B C
2 to 25 30 5 to 25 0.010 0

 

Evaluation Measurement

Calculate n-octane concentration:

Y[mg/L] = A • B • (X[ppm] + C)

Cross Sensitivity

Ethyl acetate and hydrogen sulfide are indicated with lower sensitivity. Perchloroethylene is indicated with higher sensitivity. Toluene is indicated with different sensitivity. Draeger Tube n-Octane 2 to 25 mg/L 6730201

Draeger Petroleum Hydrocarbons 100/a Tubes – 6730201

  • Simple to use
  • Requires no calibration
  • Inexpensive and portable
  • Wide variety of gases and vapors
  • 70 years of proven technology
  • Most Trusted – Draeger-Tubes have been leading the way in gas detection for over 60 years.
  • Widest Range – Over 200 different Draeger-Tubes are available for measuring over 500 gases and vapors.
  • Hassle-Free Operation – No calibration, no lubrication, no special maintenance. Always ready to go.

 

Accurate and reliable results

Draeger-Tubes with the Accuro Pump deliver the most accurate results. 60+ years of manufacturing colorimetric tubes. The bellows pump design delivers consistent volume. Individual calibration of each batch of Draeger gas detection tubes Petroleum Hydrocarbons included, accomplishes quality assurance. Every batch undergoes testing at regular intervals, throughout the two year shelf life, to guarantee accuracy over the entire life of the tubes.

Draeger Petroleum Hydrocarbons Detector Tubes

Collect the hazardous substances in the air by using a suitable medium such as activated carbon, silica gel, or molecular sieves. Then analyze the sample in a laboratory with the aid of instrumental analysis.

Suitable for complex cases

Draeger sampling tubes and systems allow identification and measurement of different substances even under difficult conditions. Use Draeger Tubes to simultaneously and accurately measure very complex mixtures of substances or cases in which several similar substances are present. Dräger Tube Petroleum Hydrocarbons 100/a has the Draeger SKU 6730201.

Dräger accuro

Fast measurement with one hand: The Dräger-Tube pump accuro allows you to use the established Dräger-Tubes to take measurements under extreme conditions. The easy to use Draeger Tube 6730201 Petroleum Hydrocarbons 100/a has already undergone calibration. It forms a perfect unit with the Dräger-Tube pump including the Draeger Safety Petroleum Hydrocarbons Tube.

 

Petroleum Hydrocarbons Draeger Tubes & CMS Handbook Draeger Tubes Apple App Draeger Tubes Google Play App
Petroleum Hydrocarbons Draeger Tubes & CMS Handbook App Store – Draeger Tubes App Play Store – Draeger Tubes App

 

What are Draeger Tubes?

Dräger-Tubes are glass vials that contain a chemical reagent that reacts to a specific chemical or family of chemicals. Draeger detector tubes are a cost-effective, fast, and reliable way to measure toxic gases anywhere.

Draeger Tube Petroleum Hydrocarbons 100/a Gas Detection Tube 6730201

For more information about this product, contact us today +1(805) 617-0987. 

 

Additional information

Weight 1 lbs
Dimensions 7 × 2 × 2 in