Sale!
draeger logo hazmat resource

Draeger Tube Perchloroethylene 2/a 8101501

$85.50

The Draeger Tube Perchloroethylene 2/a 8101501 has a measurement range of 20 to 300 ppm / 2 to 40 ppm. During measurements, color changes on the tube indicate the concentration level of the hazardous substance.

  • Box of 10 tubes
  • 2 year shelf life
Add to quote
SKU: 8101501 Category: Product Brand:

Description

The Draeger Tube Perchloroethylene 2/a 8101501 is high precision. The Dräger sampling tubes and systems provide very reliable results, even with complex compounds and mixtures of substances and used for multiple chemicals in air, liquid, oil and soil.

Dräger-Tubes for Measuring Air Samples

Application Range

  • Standard Measuring Range: 20 to 300 ppm / 2 to 40 ppm
  • Number of Strokes n: 1 / 5
  • Time for Measurement: approx. 30 s / approx. 3 min
  • Standard Deviation: ± 15 to 20 %
  • Color Change: yellow → grey blue

 

Ambient Operating Conditions

  • Temperature: 15 to 30 °C
  • Absolute Humidity: < 25 mg H2O / L

 

Reaction Principle

  • CCI2=CCI2 + MNO4- → CI2
  • CI2 + diphenylbenzidine → grey blue reaction product

At higher concentrations there may be created a reddish area at the beginning of the indicating layer

 

Cross Sensitivity

Other chlorinated hydrocarbons, free halogens and hydrogen halides are also indicated. Petroleum hydrocarbon vapors result in a shortened reading once they exceed the following concentrations: 50 ppm with 5 strokes or 500 ppm with 1 stroke.

Dräger-Tubes for Measuring Multiple Phase Samples

Application Range

Determination of volatile chlorinated hydrocarbons in multiple phase

  • Dräger-Tube: Perchloroethylene 2/a
  • Measuring range: qualitative
  • Number of Strokes (n): maximum 10
  • Typical Stroke Time: 45 to 65 s
  • Measurement Time: approx. 55 to 550 s
  • Sample Volume: 200 mL
  • Color Change: yellow white → grey blue
  • Temperature Range: 10 to 25 °C
  • pH-Measurement: not necessary

 

Information of Measurement

– Mix a multiple phase sample which consists of e.g. 250 g water, 10 g fixed phase and 10 g oil part (about 300 mL) is mixed with approx. 5 g activated coal. It must rest for 3 minutes and then be shaken for 1 min.
– 0.2 g hydrophobated peat is added and the it must be shaken for 1 minute.
– The liquid is filled into the gas wash bottle up to the 200 mL mark.

Evaluation of Measurement

The measurement evaluation is qualitative (yes or no)

Cross Sensitivity

Chlorobenzene, 1,1-dichloroethane, 1,2-dichloroethane, dichloro methane, perchloroethylene, trichloroethylene and trichloromethane are indicated. Carbon tetrachloride and 1,1,1-trichloroethane are not indicated. Draeger tube Chlorinated Hydrocarbons qualitative in multiple phase 8101501

Dräger-Tubes for Measuring Oil Samples

Application Range

Determination of volatile chlorinated hydrocarbons in oil sludges/oil emulsions

  • Dräger-Tube: Perchloroethylene 2/a
  • Measuring range: qualitative
  • Number of Strokes (n): maximum 10
  • Typical Stroke Time: 45 to 65 s
  • Measurement Time: approx. 55 to 550 s
  • Sample Volume: approx. 0.5 g
  • Color Change: yellow white → grey blue
  • Temperature Range: 10 to 25 °C
  • pH-Measurement: not necessary

 

Information of Measurement

– Approx. 0.5 g oil sample has to be shaken intensively with 1 L de-ionized water for 2 minutes in a laboratory bottle.
– The solution must be filtered through an analysis funnel with a round filter (black ribbon) directly into the gas wash bottle up to the 200 mL mark.

Evaluation of Measurement
The measurement evaluation is qualitative (yes or no)

Cross Sensitivity

Chlorobenzene, 1,1-dichloroethane, 1,2-dichloroethane, dichloro -methane, perchloroethylene, trichloroethylene and trichloromethane are indicated. Carbon tetrachloride and 1,1,1-trichloroethane are not indicated. Draeger tubes Chlorinated Hydrocarbons qualitative in oil 8101501

Dräger-Tubes for Measuring Liquid Samples

Application Range

Determination of perchloroethylene in water/waste water

  • Dräger-Tube: Perchloroethylene 2/a
  • Measuring range: 0.1 to 1 mg/L / 0.5 to 2 mg/L
  • Number of Strokes (n): 8 / 4
  • Typical Stroke Time: 45 to 65 s
  • Measurement Time: approx. 440 s / ca. 220 s
  • Sample Volume: 200 mL
  • Color Change: yellow white → grey blue
  • Temperature Range: 8 to 37 °C
  • pH-Measurement: not necessary

System Parameters

Measurement Range [mg/L] Standard Deviation [%] Temperature [°C] Parameters
B C
0.1 to 1 number of strokes n=8 25

20

20

20

20

25

8 to 12

13 to 17

18 to 22

23 to 27

28 to 32

33 to 37

0.035 0

0.031 0

0.028 0

0.026 0

0.025 0

0.023 0

0.5 to 2 number of strokes n=4 25

20

20

20

25

30

8 to 12

13 to 17

18 to 22

23 to 27

28 to 32

33 to 37

0.075 0

0.071 0

0.065 0

0.057 0

0.056 0

0.047 0

Evaluation of Measurement

Calculate perchloroethylene concentration:

Y[mg/L] = A • B • (X[ppm] + C)

Cross Sensitivity

Dichloromethane and chloroform are indicated with lower sensitivity. Trichloroethylene is indicated with nearly the same sensitivity. Petroleum hydrocarbons, benzene, carbon tetrachloride, toluene, 1,1,1-trichloroethane and xylene are not indicated. Draeger Tube Perchloroethylene 0.1 to 2 mg/L 8101501

Draeger Tube Trichloroethylene 0.1 to 1 mg/L 8101501

Application Range

Determination of trichloroethylene in water/waste water

  • Dräger-Tube: Perchloroethylene 2/a
  • Measuring range: 0.1 to 1 mg/L
  • Number of Strokes (n): 8
  • Typical Stroke Time: 45 to 65 s
  • Measurement Time: approx. 440 s
  • Sample Volume: 200 mL
  • Color Change: yellow white → grey blue
  • Temperature Range: 5 to 33 °C
  • pH-Measurement: not necessary

 

System Parameters

Measurement Range [mg/L] Standard Deviation [%] Temperature [°C] Parameters
B C
0.1 to 1 30 5 to 10

11 to 15

16 to 22

23 to 28

29 to 33

0.033 0

0.030 0

0.024 0

0.020 0

0.018 0

Evaluation of Measurement

Calculate trichloroethylene concentration:

Y[mg/L] = A • B • (X[ppm] + C)

Cross Sensitivity

Dichloromethane, chlorobenzene, 1,1-dichloroethane, 1,2 dichloroethane and chloroform are indicated with lower sensitivity. Perchloroethylene is indicated with nearly the same sensitivity. Carbon tetrachloride and 1,1,1-trichloroethane are not indicated.

Draeger Perchloroethylene 2/a Tubes – 8101501

  • Simple to use
  • Requires no calibration
  • Inexpensive and portable
  • Wide variety of gases and vapors
  • 70 years of proven technology
  • Most Trusted – Draeger-Tubes have been leading the way in gas detection for over 60 years.
  • Widest Range – Over 200 different Draeger-Tubes are available for measuring over 500 gases and vapors.
  • Hassle-Free Operation – No calibration, no lubrication, no special maintenance. Always ready to go.

 

Accurate and reliable results

Draeger-Tubes with the Accuro Pump deliver the most accurate results. 60+ years of manufacturing colorimetric tubes. The bellows pump design delivers consistent volume. Individual calibration of each batch of Draeger gas detection tubes Perchloroethylene included, accomplishes quality assurance. Every batch undergoes testing at regular intervals, throughout the two year shelf life, to guarantee accuracy over the entire life of the tubes.

Draeger Perchloroethylene Detector Tubes

Collect the hazardous substances in the air by using a suitable medium such as activated carbon, silica gel, or molecular sieves. Then analyze the sample in a laboratory with the aid of instrumental analysis.

Suitable for complex cases

Draeger sampling tubes and systems allow identification and measurement of different substances even under difficult conditions. Use Draeger Tubes to simultaneously and accurately measure very complex mixtures of substances or cases in which several similar substances are present. Dräger Tube Perchloroethylene 2/a has the Draeger SKU 8101501.

Dräger accuro

Fast measurement with one hand: The Dräger-Tube pump accuro allows you to use the established Dräger-Tubes to take measurements under extreme conditions. The easy to use Draeger Tube 8101501 Perchloroethylene 2/a has already undergone calibration. It forms a perfect unit with the Dräger-Tube pump including the Draeger Safety Perchloroethylene Tube.

 

Perchloroethylene Draeger Tubes & CMS Handbook Draeger Tubes Apple App Draeger Tubes Google Play App
Perchloroethylene Draeger Tubes & CMS Handbook App Store – Draeger Tubes App Play Store – Draeger Tubes App



What are Draeger Tubes?

Dräger-Tubes are glass vials that contain a chemical reagent that reacts to a specific chemical or family of chemicals. Draeger detector tubes are a cost-effective, fast, and reliable way to measure toxic gases anywhere.

Draeger Tube Perchloroethylene 2/a Gas Detection Tube 8101501

For more information about this product, contact us today +1(805) 617-0987.

Additional information

Weight 1 lbs
Dimensions 7 × 2 × 2 in