Sale!
draeger logo hazmat resource

Draeger Tube Ethylene Glycol 10/a 8101351

$94.50

The Draeger Tube Ethylene Glycol 10/a 8101351 has a measurement Range: 10 – 180 mg/m3.

  • Box of 10 tubes
  • 2 year shelf life
Add to quote
SKU: 8101351 Category: Product Brand:

Description

The Draeger Tube Ethylene Glycol 10/a 8101351 is high precision. The Dräger sampling tubes and systems provide very reliable results, even with complex compounds and mixtures of substances.

Application Range

  • Standard Measuring Range: 10 to 180 mg/m3
  • Corresponds to 4 to 70 ppm.
  • Number of Strokes n: 10
  • Time for Measurement: approx. 7 min
  • Standard Deviation: ± 20 to 30 %
  • Color Change: white → pink

 

Ambient Operating Conditions

  • Temperature: 10 to 35 °C
  • Absolute Humidity: 5 to 15 mg H2O / L

 

Reaction Principle

  1. OH-C2H4-OH → HCHO
  2. HCHO + C6H4(CH3)2 + H2SO4 → quinoid reaction products

 

Cross Sensitivity

The tube indicates styrene, vinyl acetate and acetaldehyde with a yellowish brown discoloration.
It is impossible to measure ethylene glycol in the presence of formaldehyde and ethylene oxide because they produce the same discoloration.

Additional Information

Break the reagent ampoule before carrying out the measurement.

Draeger Gas Detector Tubes Ethylene Glycol

  • Simple to use
  • Requires no calibration
  • Inexpensive and portable
  • Wide variety of gases and vapors
  • 70 years of proven technology
  • Most Trusted – Draeger-Tubes have been leading the way in gas detection for over 60 years.
  • Widest Range – Over 200 different Draeger-Tubes are available for measuring over 500 gases and vapors.
  • Hassle-Free Operation – No calibration, no lubrication, no special maintenance. Always ready to go.

 

Accurate and Reliable Results

Draeger-Tubes with the Accuro Pump deliver the most accurate results. 60+ years of manufacturing colorimetric tubes. The bellows pump design delivers consistent volume. Individual calibration of each batch of Draeger gas detection tubes ethylene glycol included, accomplishes quality assurance. Then, every batch undergoes testing at regular intervals, throughout the two year shelf life, to guarantee accuracy over the entire life of the tubes.

Collect the hazardous substances in the air by using a suitable medium such as activated carbon, silica gel, or molecular sieves. Then, analyze the sample in a laboratory with the aid of instrumental analysis.

Suitable for Complex Cases

Draeger sampling tubes and systems allow identification and measurement of different substances even under difficult conditions. Use Draeger Tubes to simultaneously and accurately measure very complex mixtures of substances or cases in which several similar substances are present. Dräger Tube Ethylene Glycol 10/a has the Draeger SKU 8101351.

Dräger accuro

Fast measurement with one hand: The Dräger-Tube pump accuro allows you to use the established Dräger-Tubes to take measurements under extreme conditions. The easy-to-use Dräger-Tubes have already undergone calibration and form a perfect unit with the Dräger-Tube pump including the Draeger safety ethylene glycol tube.

 

Draeger Ethylene Glycol 10/a Tubes – 8101351

Ethylene Glycol Draeger Tubes & CMS Handbook Draeger Tubes Apple App Draeger Tubes Google Play App
Ethylene Glycol Draeger Tubes
& CMS Handbook
App Store
Draeger Tubes App
Play Store
Draeger Tubes App

What are Draeger tubes used for?

Dräger-Tubes are glass vials that contain a chemical reagent that reacts to a specific chemical or family of chemicals. Draeger detector tubes are a cost-effective, fast, and reliable way to measure toxic gases anywhere.

Draeger Tube Ethylene Glycol 10/a Gas Detection Tube 8101351

For more information about the Draeger ethylene glycol detector tube, contact us today +1(805) 617-0987

Additional information

Weight 1 lbs
Dimensions 7 × 2 × 2 in

You may also like…